Main Article Content

Abstract

A simple and selective LC method is described for the determination of Metformin and Canagliflozin in tablet dosage forms. Chromatographic separation was achieved on a c18 column using mobile phase consisting of a mixture of 40 volumes of k2hpo4+NaHPO4 buffer,40 volumes of acetonitrile and 20 volumes of Methanol with detection of 251 nm. Linearity was observed in the range 75-175 µg/ml for Metformin (r2 =0.997) and 24-56 µg /ml for Canagliflozin (r2 =0.993) for the amount of drugs estimated by the proposed methods was in good agreement with the label claim.


The proposed methods were validated. The accuracy of the methods was assessed by recovery studies at three different levels. Recovery experiments indicated the absence of interference from commonly encountered pharmaceutical additives. The method was found to be precise as indicated by the repeatability analysis, showing %RSD less than 2. All statistical data proves validity of the methods and can be used for routine analysis of pharmaceutical dosage form.

Keywords

Liquid chromatography (LC) RSD Relative standard deviation R2 Correlation coefficient

Article Details